Check Valve Series

Product drawing»

Structural drawing»

You are here: News > News Detail

Gas Blowby case

2010-10-28

Trying to calculate the gas blowby case flowrate from high pressure separator to low pressure separator. I am wondering if I can use the max Cv of the liquid level control valve.
The Cv by definition is the related to the flow rate of water at 1 psi pressure drop. In gas blowby case we try to find the gas flow rate. By this definition of Cv, Is it applicable to gas flow calculation?
Cv is related to volumetric flow and dp, then by using a different formulation (to consider gas expansion effects) and proper density you can use CV to calculate the gas flow through the valve (see Masonelian, ISA etc. formulations), however in addition to gas properties there are several parameters as valve plug form etc. which should be considered to obtain a good estimate...


MORE NEWS

  • Air Release Valves
  • Atmospheric pressure effect on a open end pipe
  • Stellite on ball
  • Valve sizing for flashing liquids
  •  Kaiweixi Valve Group Co., Ltd.
    Kaiweixi check valve Contact Kaiweixi
    Zhejiang Shanliu Valve Technology Co., Ltd.
    Shanliu Check Valve Contact Shanliu
    Shanghai FengQi Industrial Development CO., Lid.
    FengQi Check Valve Contact FengQi
    Shanghai MeiYan Yi Pump & Valve Co., Ltd.
    MeiYan Yi check valve Contact MeiYan Yi