Replacing a ball valve in the loft
I have a cold water tank in the loft, and my overflow pipe drips
outside, I think it is because the ball valve may be long overdue to be
changed. Is this a reason for the overflow to be dripping.
1) Check if water is dripping out of the valve when it should be
shut.
2) If it is then try adjusting the arm to provide more closure
force. A modern valve can be adjusted by moving the ball down, an
older one needs to be bent downwards *gently*. This may cure it, but
is only a temporary fix.
3) Find out what sort of valve it is. There are books and no doubt
web sites which will tell you. If it is a type with a washer extract
this and see if it is worn, if it is replace. Before doing this turn
off the mains water.
4) Complete replacement of the valve may be necessary, but can
usually be avoided.